Close Go back Collapse all sections
Process Data set: III/A 42,5R/SRC (en) en es

Key Data Set Information
Location ES
Geographical representativeness description España
Reference year 2025
Name
III/A 42,5R/SRC
Use advice for data set Declared modules: A1 Raw materials supply A2 Transport A3 Manufacturing
Technical purpose of product or process III/A 42.5R/SRC cement is a sulfate-resistant blast furnace cement specially formulated for the production of both mass and reinforced concretes that must withstand aggressive environmental conditions. Thanks to its high compressive strength of 42.5 MPa at 28 days, this cement provides excellent durability and structural capacity. In addition, its formulation includes a significant reduction in clinker content, which helps decrease CO₂ emissions during production, making this cement a more sustainable option without compromising performance. Its resistance to sulfates and seawater makes it the ideal choice for constructions near coasts or in soils with high sulfate content. This cement strictly complies with EN 197-1:2011, which regulates the requirements for common cements, and with EN 80303-1:2017, which establishes the specific requirements for sulfate-resistant cements, ensuring that its composition and properties are perfectly adapted to these conditions. It also complies with the RC-16 guidelines, included in R.D. 256/2016 on cement reception, as well as with the Structural Code approved in June 2021.
Classification
Class name : Hierarchy level
  • The International EPD System: EPD de un producto individual
General comment on data set Sulfate-resistant blast furnace cement, designed for use in both mass and reinforced concretes. Suitable for concretes in chemically aggressive environments, in the presence of sulfates, or in marine environments.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 0.0 kg/m^3
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025/09/02 - 2030/09/02
Technological representativeness
Technology description including background system Product components: Composition of III/A 42.5R/SRC cement according to standard: Clinker: 35–64% Blast furnace slag: 36–65% Minor components: 0–5% These values refer to the cement core, excluding calcium sulfate and any additives.: Bulk cement.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 53.5
  • ND
  • 3.27
  • 77.2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 53.5
  • ND
  • 3.27
  • 77.2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.33E+3
  • ND
  • 389
  • 3.6E+2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.33E+3
  • ND
  • 389
  • 3.6E+2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.0086
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.0513
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 1.04
  • ND
  • 0.586
  • 0.124
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 7.3
  • ND
  • 0.00275
  • 0.0988
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 418
  • ND
  • 27.1
  • 14.5
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.158
  • ND
  • 0.0201
  • 0.116
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 425
  • ND
  • 27.1
  • 14.8
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.25E+3
  • ND
  • 367
  • 347
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000052
  • ND
  • 0.0000504
  • 0.0000172
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.037
  • ND
  • 0.00132
  • 0.00529
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.298
  • ND
  • 0.135
  • 0.0198
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 425
  • ND
  • 27.1
  • 14.8
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.0000108
  • ND
  • 0.0000056
  • 0.00000102
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 4.57
  • ND
  • 0.401
  • 0.0552
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 3.4
  • ND
  • 1.5
  • 0.205
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • -16.4
  • ND
  • 0.986
  • 9.56
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Eco-toxicity - freshwater (ETP-fw) 2
  • 2.2E+3
  • ND
  • 2.6E+2
  • 221
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human toxicity, cancer effect (HTP-c) 2
  • 1.82E-7
  • ND
  • 1.6E-8
  • 4.88E-9
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human toxicity, non-cancer effects (HTP-nc) 2
  • 0.00000277
  • ND
  • 2.1E-7
  • 1.49E-7
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND